RTU 101-IMS
for monitoring insulation- and loop resistance in copper cables
The monitoring station RTU 101-IMS is used to detect the penetration of moisture in copper cables, their squeezing or damage.
The readings of the 10 measurement channels, regarding insulation and loop resistance, are evaluated by the RTU 101-IMS according to individual user programmed parameters.
Threshold exceedings cause automatic reports like warnings, alarms etc. to assigned receiving stations.
The UMS server permanently polls the actual measurement and system data via intranet (Ethernet, TCP/IP). It evaluates the sensing points states and stores all data in the database of the UMS server.
All connections and control units are stored in awall mount housing. The connections are fixed by screws and clamps ensuring an easy and cost effective mounting without the need ofexpensive special cables.
Ordering Data
Monitoring Station RTU 101-IMS in wall mount housing with pre-assembled ethernet cable 30 V Test voltage 90 V Test voltage |
|
External power supply 230 V AC | Order-no.062025.000 |
19" 6HU adapter for mounting in 19" cabinets or racks | Order-no. 061713.000 |
Downloads
Technical Data
Supply voltage | 21 .. 72 V DC | |
Power consumption | typ. 10 VA DC | |
No. of measurement channels | 10 for loop- and insulation resistance each | |
Measurement range | Insulation measurement 0,01 ... 500 MΩ | Loop resistance measurement 50 ... 20.000 Ω |
Resolution | up to 0,01 MΩ | up to 1 Ω |
Max. measurement error | 10% of measured value ± 50 kΩ | ± 3% of measured value |
Test voltage | 30 V or 90 V DC | |
Local alarm signalisation | 13 dry contacts | |
Operating temperature | 0 .. +40 °C | |
Storage temperature | -5 .. +60 °C | |
EMC | 61000-6-1/2 and 61000-6-3/4 | |
Data back up | Battery buffer (2 years) | |
Dimensions (H x W x D) | 237 x 355 x 150 mm | |
Weight | approx. 3,2 kg |