Skip to main navigation Skip to main content Skip to page footer

FMA 200C

Digital Flowmeter

The FMA 200C is a highly accurate and reliable instrument to monitor pressurized cables. It may be used as a local measuring device or as an adressable sensor within the LANCIER monitoring system. The airflow measurement is pressure-independent at a range of 0 - 200 l/h. Actual values are shown at the 3 digit LC-display with a resolution of 1 l/h. The FMA 200C signalises the exceeding of programmed thresholds by means of a signal LED and the closing of an alarm relay contact. A built-in key is used to acknowledge the local signal.

The distribution block with integrated electrical and pneumatical bus system can house up to five FMA 200C without the need of costly connectors. Old LANCIER distribution blocks with mechanical flow meters can be conveniently replaced one-to-one.

Ordering Data

Digital Flowmeter FMA 200C
Module with display and keys. Signal output via dry contacts

Order-no. 064952.100
Distribution block for 1-5 FMA 200C Order-no. 064950.000
Blindplate for FMA-block Order-no. 064954.000
19" installation kit for one distribution block
(for installation into 19" wall-mount cabinets and front doors of RTS equipment)


Order-no. 064955.000
Installation kit for the first distribution block
(for replacement of flow indicators and expansions)

Order-no. 065897.000
Pneumatic installation kit for one FMA 200C
(Output connector for new RTS equipment, 19" wall-mount cabinets and expansions)


Order-no. 065898.000
Common input air filter(for installation into PE 10/7 hose when connecting to cable type PWE2Y)
Order-no. 071011.000
Micro air filter add-on kit for RTS 2802
(for installation of FMA 200C in RTS 2802)

Order-no. 071012.000
Blindplate 19", 2.5 HU Order-no. 064498.000

Technical Data

Measuring range 0 ... 200 l/h
Display resolution 1 I/h
Max. measuring error ±5 % FS, ±1 Digit at +20 °C
Max. temperature drift ±0,15 % FS/°C
Operating pressure 0 ... 1 bar
Operating voltage 36 ... 72 V= / 2,5 VA
Operating temperature 0 ... +50 °C
Storage temperature -30 ... +80 °C
Admissible humidity 0 .. 95 % rel. humidity, non-condensing
Signal output dry contact, max. 100 V= / 0.1 A=
Remote reading Tx-bus
Frequency range 1000 Hz ... 2000 Hz
Resolution 1 Hz 0,2 l/h
Dimensions
   Flowmeter (WxDxH)
   Manifold block (WxDxH)

64,2 x 106,2 x 110,2 mm
322 x 150 x 110,2 mm
Weight
   Flowmeter
   Manifold block equipped with 5 flowmeters

approx. 0,18 kg
approx. 1,80 kg